  • Digital Earth Resistance Tester

    ERT-1501 - Neutronics Manufacturing Co.

    Electronic Digital Earth Resistance Tester is direct replacement of the conventional hand generator type tester. It is designed for measurement of the resistance of earthing used in the electrical equipment as well as for measurement of ground resistivity. It can be used for measurements of the other low regular and liquid resistances. It can also be used for measurement of voltage AC, voltage DC and resistance. This instrument finds wide application for testing earthing installation in power based industries, telecommunication networks and electrical traction systems etc.

  • Dynamic Micro Ohm Meter

    PRIME 200 - EUROSMC, S.A.

    It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 200 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.

  • Dynamic Micro Ohm Meter

    PRIME 600 - EUROSMC, S.A.

    It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 600 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.

  • Rack Mount Cable Tester

    AudioJog Rack - CableJoG Ltd

    There are 2 rows of 6 LED's corresponding to each of the possible connector pins and one for the screen (or ground) connection. As each pin is activated, the LED's indicate all connections associated with that pin, so that short, open and crossed circuits can be easily found. The LED's also show the possibility of high resistance or leakage connections.

  • Surface Resistance Meter

    WL MIDGET - Walter G. Legge Company Inc.

    WL MIDGET Surface Resistance Meter is an ultra-wide range, battery operated, portable instrument for measuring Surface Resistivity and Resistance to Ground of virtually any flat surface conforming to ASTM D-257 standard method by using recommended parallel bar sensing probe. Gives simple, repeatable measurements of conductive, static dissipative, and insulative surfaces. Ranging is automatic due to the use of high-speed OP-AMP Integrated circuits being linear, with changeover points +1/2 decade on a logarithmic scale. Repeatability equals + 5%.

  • Sensing Resistors

    Resistive Voltage Dividers - Hilkar

    NGR Sensing Resistors are attached in parallel to the neutral grounding resistor. The sensing resistor allows a protective relay to detect a resistor failure in a continuous manner. Sensing Resistors are used in combination with neutral grounding resistor monitor relays. The relay measures neutral grounding resistance, neutral grounding resistor current and neutral to ground voltage. The relay continuously measures neutral grounding resistor ohmic value in an unfaulted system and it trips on if neutral grounding resistance varies from its calibrated value.

  • DC to 100MHz

    1394A - Ballentine Laboratories, Inc.

    Nominal Heater Current: 5 mA rms,Max. Heater Current: 7.5 mA rmsCouple Output: 7 mV ± 12% at nominal heater current.Couple Resistance: 8 W ± 20%.Maximum DC Reversal Error: ± 0.04%Couple Output Voltage to Heater (ground): ± 50 V (dc + acpk-pk) max.

  • Test Probes

    AUTO DIAGNOSTECH LTD

    Our innovative Test Probes are the upgrade version of Auto Multi Meter. It can perform multiple circuit system test such as power supply feed, voltage and resistance measurement, continuity test, ground test, polarity check and components activation.

  • Ohm-Stat Digital Display Megohmmeter

    Static Solutions Inc.

    Measures resistivity RTT, RTV, and RTG 103-1012 ohms/sq., ohms, ohm-cmRelative humidity 10% 90% RHTemperature 32oF 100oFDigital display: easy to interpretNIST calibration includedIncludes chair probe to measure smocks, earth ground, chairs, and resistance probes: $400 value for freeResistivity probe built in the bottom of meterProduct conforms to the ESD S.20.20 spec standardsCE mark includedThe kit includes, two (5) lb probes, coil cords, hard carrying case, battery, 110v or 220v adaptor, garment clips, chair probe, and ground circuit tester

  • Multiplexer

    SC6540 - Associated Research

    Our patented SC6540 modular scanning matrix pioneered the largest productivity improvement in the electrical safety compliance industry in years. With up to 16 independent high voltage or high current channels in a convenient 2U design, the SC6540 can be customized in 10 different configurations for multi-point Hipot, Ground Bond, Insulation Resistance and Leakage Current testing.

  • Motor Winding Ohmmeter

    RMO-M Series - IBEKO Power AB

    The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement

  • Electric Shock Protection Analysis

    ETAP Enterprise

    60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel

  • Wristat Tester

    WT 25-4145.26M - Walter G. Legge Company Inc.

    WT 25-4145.26M Wristat Tester is available to comply with D.O.D. 4145.26 specifications. The WT25-4145.26M Wristat Tester is designed to test the integrity of our WRISTAT in a fast, efficient, and simple manner. All the elements of the WRISTAT – continuity of the strap, integrity of the protective resistor, and satisfactory strap to skin contact – are easily confirmed by pressing the top cover of the WT25-4145.26M. The operator (wearer) is tested for a resistance to ground of greater than 250K ohms and less than1,200,000 ohms. The upper limit notifies you of an unacceptably high resistance value (IE possible loss of effective dissipation) and the lower limit warns of unsafe low resistance (possible risk of electric shock from surrounding motors, live wires etc.). The unit is not switchable.

  • High Resistance Neutral Grounding Devices

    Hilkar

    HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.

  • Wristat Tester

    WT25 - Walter G. Legge Company Inc.

    The WT25 WRISTAT Tester is designed to test the integrity of our WRISTAT in a fast, efficient and simple manner. All of the elements of the WRISTAT - continuity of the strap, integrity of the protective resistor, and satisfactory strap to skin contact are easily confirmed by pressing the top cover of the WT25. The operator (wearer) is tested for a resistance to ground of greater than 750K ohms and less than 10M (switchable to 100M ohms).